{"id":12190,"date":"2025-03-05T14:38:53","date_gmt":"2025-03-05T13:38:53","guid":{"rendered":"https:\/\/unipower-se.tbwebsite.com\/?p=12190"},"modified":"2025-03-05T15:10:11","modified_gmt":"2025-03-05T14:10:11","slug":"matning-av-elkvalitetsstorningar-i-en-elbussdepa","status":"publish","type":"post","link":"https:\/\/unipower-se.tbwebsite.com\/sv\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/","title":{"rendered":"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 &#8211; Fallstudie"},"content":{"rendered":"<p><strong>I denna fallstudie unders\u00f6ks hur avancerad teknik f\u00f6r m\u00e4tning av elkvalitet underl\u00e4ttade diagnostiseringen av allvarliga elkvalitetsst\u00f6rningar i en bussdep\u00e5. Dessa st\u00f6rningar, som varken bussoperat\u00f6ren eller busstillverkaren inledningsvis h\u00e4nf\u00f6rde till elkvalitetsproblem, sp\u00e5rades slutligen till brister i dep\u00e5ns laddningsinfrastruktur.<\/strong><\/p>\n<h4>Bakgrund<\/h4>\n<p>En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. Anl\u00e4ggningen inneh\u00f6ll AC-laddare (22 kW) avsedda f\u00f6r minibussar och DC-snabbladdare (200 kW) f\u00f6r st\u00f6rre elbussar. Dep\u00e5operat\u00f6rerna observerade att AC-laddarna periodvis inte fungerade n\u00e4r DC-laddarna anv\u00e4ndes. Dessa problem p\u00e5verkade tillg\u00e4ngligheten f\u00f6r fordonen och den \u00f6vergripande drifts\u00e4kerheten. Grundorsaken till dessa st\u00f6rningar var inte fastst\u00e4lld f\u00f6rr\u00e4n en omfattande elkvalitetsanalys genomf\u00f6rdes.<\/p>\n<h4>Diagnostisk bed\u00f6mning<\/h4>\n<p>En unders\u00f6kning av elkvaliteten visade att st\u00f6rningarna berodde p\u00e5 att det saknades n\u00f6dv\u00e4ndiga elektriska filter i likstr\u00f6msladdarna. Utan dessa filter orsakade driften av likstr\u00f6msladdarna betydande harmoniska st\u00f6rningar i den lokala sp\u00e4nningen, vilket st\u00f6rde stabiliteten hos v\u00e4xelstr\u00f6msladdarna.<\/p>\n<p><a href=\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/Case-Study-Electrical-bus-depot-in-Sweden.pdf\" target=\"_blank\" rel=\"noopener\">L\u00e4s hela artikeln h\u00e4r.<\/a> (p\u00e5 engelska)<\/p>\n<p><a href=\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/Vinga-bus-laddstation_EIFS2025-02-20-123608.pdf\" target=\"_blank\" rel=\"noopener\">Ladda ner EIFS rapporten h\u00e4r.<\/a> (p\u00e5 engelska)<\/p>\n<p><em>Bild: Flygvy \u00f6ver bussdep\u00e5n. Stora bussar laddas med likstr\u00f6m, minibussar laddas med v\u00e4xelstr\u00f6m (laddning \u00f6ver natten).<\/em><\/p>","protected":false},"excerpt":{"rendered":"<p>I denna fallstudie unders\u00f6ks hur avancerad teknik f\u00f6r m\u00e4tning av elkvalitet underl\u00e4ttade diagnostiseringen av allvarliga elkvalitetsst\u00f6rningar i en bussdep\u00e5. Dessa st\u00f6rningar, som varken bussoperat\u00f6ren eller busstillverkaren inledningsvis h\u00e4nf\u00f6rde till elkvalitetsproblem, sp\u00e5rades slutligen till brister i dep\u00e5ns laddningsinfrastruktur. Bakgrund En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. Anl\u00e4ggningen inneh\u00f6ll AC-laddare (22 kW) avsedda f\u00f6r [&hellip;]<\/p>","protected":false},"author":9,"featured_media":12185,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[11],"tags":[],"class_list":["post-12190","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nyheter"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 - Fallstudie - Unipower AB<\/title>\n<meta name=\"description\" content=\"En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. En omfattande elkvalitetsanalys genomf\u00f6rdes\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/unipower-se.tbwebsite.com\/sv\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 - Fallstudie - Unipower AB\" \/>\n<meta property=\"og:description\" content=\"En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. En omfattande elkvalitetsanalys genomf\u00f6rdes\" \/>\n<meta property=\"og:url\" content=\"https:\/\/unipower-se.tbwebsite.com\/sv\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/\" \/>\n<meta property=\"og:site_name\" content=\"Unipower AB\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/UnipowerSweden\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-05T13:38:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-05T14:10:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1068\" \/>\n\t<meta property=\"og:image:height\" content=\"748\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"walther\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Skriven av\" \/>\n\t<meta name=\"twitter:data1\" content=\"walther\" \/>\n\t<meta name=\"twitter:label2\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/\"},\"author\":{\"name\":\"walther\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/person\/b848d2252d214ba8f811ea351ee20dea\"},\"headline\":\"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 &#8211; Fallstudie\",\"datePublished\":\"2025-03-05T13:38:53+00:00\",\"dateModified\":\"2025-03-05T14:10:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/\"},\"wordCount\":220,\"publisher\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg\",\"articleSection\":[\"Nyheter\"],\"inLanguage\":\"sv-SE\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/\",\"url\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/\",\"name\":\"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 - Fallstudie - Unipower AB\",\"isPartOf\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg\",\"datePublished\":\"2025-03-05T13:38:53+00:00\",\"dateModified\":\"2025-03-05T14:10:11+00:00\",\"description\":\"En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. En omfattande elkvalitetsanalys genomf\u00f6rdes\",\"breadcrumb\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage\",\"url\":\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg\",\"contentUrl\":\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg\",\"width\":1068,\"height\":748,\"caption\":\"Measuring PQ Issues in an Electrical Bus Depot - Case Study\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/unipower-se.tbwebsite.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 &#8211; Fallstudie\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#website\",\"url\":\"https:\/\/unipower-se.tbwebsite.com\/\",\"name\":\"Unipower AB\",\"description\":\"The Leading Edge in Electric Power Quality Instruments\",\"publisher\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/unipower-se.tbwebsite.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#organization\",\"name\":\"Unipower AB\",\"url\":\"https:\/\/unipower-se.tbwebsite.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2022\/10\/Unipower-logo-blue.png\",\"contentUrl\":\"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2022\/10\/Unipower-logo-blue.png\",\"width\":396,\"height\":192,\"caption\":\"Unipower AB\"},\"image\":{\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/UnipowerSweden\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/person\/b848d2252d214ba8f811ea351ee20dea\",\"name\":\"walther\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c49a449ed72c21a2424cfa5669b6de5758a19b00c69517cbb0a98413c45e468c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c49a449ed72c21a2424cfa5669b6de5758a19b00c69517cbb0a98413c45e468c?s=96&d=mm&r=g\",\"caption\":\"walther\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 - Fallstudie - Unipower AB","description":"En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. En omfattande elkvalitetsanalys genomf\u00f6rdes","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/unipower-se.tbwebsite.com\/sv\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/","og_locale":"sv_SE","og_type":"article","og_title":"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 - Fallstudie - Unipower AB","og_description":"En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. En omfattande elkvalitetsanalys genomf\u00f6rdes","og_url":"https:\/\/unipower-se.tbwebsite.com\/sv\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/","og_site_name":"Unipower AB","article_publisher":"https:\/\/www.facebook.com\/UnipowerSweden\/","article_published_time":"2025-03-05T13:38:53+00:00","article_modified_time":"2025-03-05T14:10:11+00:00","og_image":[{"width":1068,"height":748,"url":"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg","type":"image\/jpeg"}],"author":"walther","twitter_card":"summary_large_image","twitter_misc":{"Skriven av":"walther","Ber\u00e4knad l\u00e4stid":"1 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#article","isPartOf":{"@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/"},"author":{"name":"walther","@id":"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/person\/b848d2252d214ba8f811ea351ee20dea"},"headline":"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 &#8211; Fallstudie","datePublished":"2025-03-05T13:38:53+00:00","dateModified":"2025-03-05T14:10:11+00:00","mainEntityOfPage":{"@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/"},"wordCount":220,"publisher":{"@id":"https:\/\/unipower-se.tbwebsite.com\/#organization"},"image":{"@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage"},"thumbnailUrl":"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg","articleSection":["Nyheter"],"inLanguage":"sv-SE"},{"@type":"WebPage","@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/","url":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/","name":"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 - Fallstudie - Unipower AB","isPartOf":{"@id":"https:\/\/unipower-se.tbwebsite.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage"},"image":{"@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage"},"thumbnailUrl":"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg","datePublished":"2025-03-05T13:38:53+00:00","dateModified":"2025-03-05T14:10:11+00:00","description":"En bussdep\u00e5 med b\u00e5de AC- och DC-laddningsinfrastruktur drabbades av driftst\u00f6rningar. En omfattande elkvalitetsanalys genomf\u00f6rdes","breadcrumb":{"@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#primaryimage","url":"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg","contentUrl":"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2025\/03\/bus_depot_case_study.jpg","width":1068,"height":748,"caption":"Measuring PQ Issues in an Electrical Bus Depot - Case Study"},{"@type":"BreadcrumbList","@id":"https:\/\/unipower-se.tbwebsite.com\/nyheter\/matning-av-elkvalitetsstorningar-i-en-elbussdepa\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/unipower-se.tbwebsite.com\/"},{"@type":"ListItem","position":2,"name":"M\u00e4tning av elkvalitetsst\u00f6rningar i en elbussdep\u00e5 &#8211; Fallstudie"}]},{"@type":"WebSite","@id":"https:\/\/unipower-se.tbwebsite.com\/#website","url":"https:\/\/unipower-se.tbwebsite.com\/","name":"Unipower AB","description":"The Leading Edge in Electric Power Quality Instruments","publisher":{"@id":"https:\/\/unipower-se.tbwebsite.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/unipower-se.tbwebsite.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/unipower-se.tbwebsite.com\/#organization","name":"Unipower AB","url":"https:\/\/unipower-se.tbwebsite.com\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/logo\/image\/","url":"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2022\/10\/Unipower-logo-blue.png","contentUrl":"https:\/\/unipower-se.tbwebsite.com\/wp-content\/uploads\/2022\/10\/Unipower-logo-blue.png","width":396,"height":192,"caption":"Unipower AB"},"image":{"@id":"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/UnipowerSweden\/"]},{"@type":"Person","@id":"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/person\/b848d2252d214ba8f811ea351ee20dea","name":"walther","image":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/unipower-se.tbwebsite.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c49a449ed72c21a2424cfa5669b6de5758a19b00c69517cbb0a98413c45e468c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c49a449ed72c21a2424cfa5669b6de5758a19b00c69517cbb0a98413c45e468c?s=96&d=mm&r=g","caption":"walther"}}]}},"_links":{"self":[{"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/posts\/12190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/comments?post=12190"}],"version-history":[{"count":4,"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/posts\/12190\/revisions"}],"predecessor-version":[{"id":12200,"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/posts\/12190\/revisions\/12200"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/media\/12185"}],"wp:attachment":[{"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/media?parent=12190"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/categories?post=12190"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/unipower-se.tbwebsite.com\/sv\/wp-json\/wp\/v2\/tags?post=12190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}